logo
Αρχική Σελίδα ΠροϊόνταΑισθητήρας αερίου

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

Πιστοποίηση
ΚΙΝΑ ShenzhenYijiajie Electronic Co., Ltd. Πιστοποιήσεις
ΚΙΝΑ ShenzhenYijiajie Electronic Co., Ltd. Πιστοποιήσεις
Είμαι Online Chat Now

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector
YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

Μεγάλες Εικόνας :  YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

Λεπτομέρειες:
Τόπος καταγωγής: Βρετανία
Μάρκα: CITY
Αριθμό μοντέλου: ΚΛ2-Α1
Πληρωμής & Αποστολής Όροι:
Ποσότητα παραγγελίας min: 1
Τιμή: Διαπραγματεύσιμα
Συσκευασία λεπτομέρειες: Παλετικός
Χρόνος παράδοσης: 5-8 μέρες
Όροι πληρωμής: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Δυνατότητα προσφοράς: 1500

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

περιγραφή
Παρεμβαίνοντας αέριο: αέρια CL2 Σφάλμα επαναληψιμότητας: ± 2% σε διάστημα 6 μηνών
Σήμα εξόδου: Αναλογική τάση Επαναληψιμότητα: < ±2 ισοδύναμο CL2
Ζωή αποθήκευσης: 2 χρόνια Θερμοκρασία λειτουργίας: 0 ℃ ~+50 ℃
Χρήση: Φορητή λειτουργία Εύρος ανίχνευσης: 0 ~ 20 PPM
Επισημαίνω:

chlorine gas electrochemical sensor 20ppm

,

portable chlorine gas detector sensor

,

YJJ CL2-A1 gas sensor

Product Description:

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector

 

Features:

I. Core Parameters (Electrochemical Cl₂ Sensor)

Detected Gas: Chlorine Gas Cl₂

Measurement Range: 0 - 20 ppm (ensuring accuracy range)

Short-term Overload: Maximum tolerance 50 ppm

Sensitivity: -350 ~ -750 nA/ppm (under 10 ppm chlorine gas conditions)

Response Time T90: < 60 s (typical value < 40 s)

Resolution: < 0.02 ppm (able to detect ppb-level minor leaks)

Zero Point Current: ±0.4 ppm equivalent value

Linear Range: 0 - 5 ppm with good linearity, full range error ±1.5 ppm

Environmental Conditions

Temperature: -20℃ ~ +50℃

Humidity: 15% - 90% RH (no condensation)

Air Pressure: 80 - 120 kPa

Service Life: ≥ 24 months (original factory 24-month warranty)

Long-term Drift: Zero-point drift < 0.05 ppm/year; Sensitivity annual drift < 10%

Physical Dimensions: Φ20.2 × 16.5 mm, Weight < 6g, Standard 4-pin A-series package

Cross-Interference: SO₂ interference is small, CO, H₂, ethylene, etc. interference are extremely low, suitable for complex working conditions

II. Product Principle

Fuel cell type electrochemical sensor, chlorine gas undergoes redox reaction on the electrode surface, outputting a weak current signal, the current size is proportional to the chlorine gas concentration, the rear-end circuit converts the current into concentration values.

III. Main Applications

1) Instrument Integration (OEM preferred)

Portable chlorine gas detector, single toxic gas alarm instrument

Fixed online chlorine gas transmitter, gas monitoring probe

Industrial online monitoring module, PLC gas collection module

2) Industry Application Scenarios

Water supply / sewage treatment plants

Chlorine gas leakage monitoring in water disinfection sections, chlorination rooms, liquid chlorine steel cylinder warehouses, preventing personnel poisoning.

Chlor-alkali chemical industry, PVC synthesis production line

Pointed monitoring of minor leaks at chlorine gas pipelines, valves, reactors, liquid chlorine pumps sealing areas.

Swimming pool, swimming hall disinfection system

Monitoring of chlorine compound volatile gas concentration to ensure indoor venue occupational safety.

 fine chemicals

Tail gas and pipeline leakage detection in chlorination synthesis process workshops.

Semiconductor electronics industry

Early warning of dry etching chlorine process exhaust gas, machine gas pipeline leakage.

Environmental protection supervision, laboratory

Occupational health toxic gas detection, emergency inspection equipment.

 

Specifications:

Detected Gas CL2
Packaging 4-series
Measurement Range 0 - 20 ppm
Short-term Overload 500 ppm
Sensitivity 700 ± 250 nA/ppm

 

YJJ CL2-A1 Chlorine Gas Electrochemical Sensor 0 - 20ppm for Portable Chlorine Gas Detector 0

Στοιχεία επικοινωνίας
ShenzhenYijiajie Electronic Co., Ltd.

Υπεύθυνος Επικοινωνίας: Miss. Xu

Τηλ.:: 86+13352990255

Στείλετε το ερώτημά σας απευθείας σε εμάς (0 / 3000)